{"product_id":"49agm-battery-auto-part","title":"ACDelco Gold Battery 49AGM","description":"\u003c!-- XPART_FIRE_LANE_AUTO_FORMAT_V1 --\u003e\u003cdiv class=\"xp xp-auto\" data-xpart-format=\"XPART_SALES_FORMAT_V3\" data-xpart-domain=\"automotive\"\u003e\n\u003cstyle\u003e\/* XPART_SALES_FORMAT_V3 *\/.xp{font-family:Arial,sans-serif;color:#222;line-height:1.55}.xp *{box-sizing:border-box}.xp .hero{background:linear-gradient(135deg,rgba(0,0,0,.86) 55%,rgba(0,0,0,.45)),url('https:\/\/cdn.shopify.com\/s\/files\/1\/0897\/7783\/2225\/files\/4444444444444444.png?v=1777040489') center\/cover no-repeat;padding:34px 28px;border-radius:14px;color:#fff;margin-bottom:20px}.xp .label{display:inline-block;background:#d71920;color:#fff;font-weight:800;font-size:13px;padding:7px 12px;border-radius:999px;margin-bottom:12px}.xp .hero h2{color:#fff!important;font-size:30px;line-height:1.15;margin:0 0 12px}.xp .hero p{color:#fff}.xp .specs{display:flex;gap:8px;flex-wrap:wrap}.xp .specs span{background:rgba(255,255,255,.14);border:1px solid rgba(255,255,255,.28);padding:6px 10px;border-radius:999px;font-size:13px}.xp h2{font-size:23px;margin:28px 0 12px}.xp .grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(185px,1fr));gap:12px}.xp .card{border:1px solid #e6e6e6;border-radius:10px;padding:14px;background:#fff}.xp .card strong{display:block;color:#d71920;margin-bottom:4px}.xp .box,.xp .note{background:#f7f7f7;padding:14px 16px;border-radius:8px}.xp .box{border-left:4px solid #d71920}.xp .trust{border:1px solid #e5e5e5;padding:18px;border-radius:10px;margin:18px 0}.xp .trust strong{color:#1a7a3c}.xp ul{padding-left:22px}\u003c\/style\u003e\n\u003csection class=\"hero\"\u003e\u003cdiv class=\"label\"\u003eAUTOMOTIVE PART\u003c\/div\u003e\n\u003ch2\u003eACDelco Gold Battery 49AGM\u003c\/h2\u003e\n\u003cp\u003eBattery, CCA:900 RC:160 AH:95, Gold AGM 36 Month Warranty\u003c\/p\u003e\n\u003cdiv class=\"specs\"\u003e\n\u003cspan\u003ePart 49AGM\u003c\/span\u003e\u003cspan\u003eACDelco Gold\u003c\/span\u003e\u003cspan\u003eBattery\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003cdiv class=\"trust\"\u003e\n\u003cstrong\u003eMatch your exact vehicle configuration to the verified applications below.\u003c\/strong\u003e\u003cbr\u003eConfirm the year, make, model, engine, drivetrain and required position before ordering.\u003c\/div\u003e\n\u003ch2\u003eIs This the Right Part?\u003c\/h2\u003e\n\u003cdiv class=\"grid\"\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e49AGM\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003eACDelco Gold\u003c\/div\u003e\n\u003cdiv class=\"card\"\u003e\n\u003cstrong\u003ePart Type\u003c\/strong\u003eBattery\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003ePart Details\u003c\/h2\u003e\n\u003cp class=\"note\"\u003eAdditional specifications are pending verification.\u003c\/p\u003e\n\u003c!-- XPART_AI_AUTO_FITMENT_START --\u003e\u003csection class=\"xp-vehicle-fitment\" data-xpart-fitment-hash=\"636bb7b618a56252f851adc349c014da935f91ec7f309afe47cf9fc00db2c95a\" data-application-count=\"1853\"\u003e\u003cstyle\u003e.xp-vehicle-fitment{font-family:Arial,sans-serif;margin:24px 0;color:#222}.xp-vehicle-fitment h2{font-size:24px}.xp-vehicle-fitment .xp-fit-scroll{max-height:520px;overflow:auto;border:1px solid #ddd;border-radius:8px}.xp-vehicle-fitment table{width:100%;border-collapse:collapse;font-size:14px}.xp-vehicle-fitment th,.xp-vehicle-fitment td{text-align:left;padding:10px;border-bottom:1px solid #ddd;vertical-align:top}.xp-vehicle-fitment th{background:#171717;color:#fff;position:sticky;top:0}.xp-vehicle-fitment summary{cursor:pointer;font-weight:700;padding:12px;color:#b5131a}\u003c\/style\u003e\n\u003ch2\u003eVerified Vehicle Fitment\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMake:\u003c\/strong\u003e Alfa Romeo, Aston Martin, Audi, BMW, Bentley, Cadillac, Chevrolet, Dodge, Ferrari, Ford, Freightliner, GMC, Jaguar, Jeep, Kia, Land Rover, Lincoln, Maserati, Maybach, Mercedes-Benz, Porsche, Ram, Rolls-Royce, Toyota, Volkswagen, Volvo\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 313 verified models — see exact combinations below.\u003cbr\u003e\u003cstrong\u003eYears:\u003c\/strong\u003e 1994–2027 — varies by model and configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCheck before ordering:\u003c\/strong\u003e Match the year, make, model, position, and every engine, transmission or other restriction in the same row. Listed years do not apply to every model.\u003c\/p\u003e\n\u003cdetails\u003e\u003csummary\u003eView vehicle applications (746 configuration groups)\u003c\/summary\u003e\u003cdiv class=\"xp-fit-scroll\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eYears\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMake\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePosition\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eEngine \/ transmission \/ notes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eAlfa Romeo\u003c\/td\u003e\n\u003ctd\u003eGiulia\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE battery is EFB (Enhanced Flooded Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eAlfa Romeo\u003c\/td\u003e\n\u003ctd\u003eGiulia\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Sold Country: United States; OE battery is EFB (Enhanced Flooded Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eAlfa Romeo\u003c\/td\u003e\n\u003ctd\u003eGiulia\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.9 V6; OE battery is EFB (Enhanced Flooded Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019, 2023\u003c\/td\u003e\n\u003ctd\u003eAlfa Romeo\u003c\/td\u003e\n\u003ctd\u003eStelvio\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE battery is EFB (Enhanced Flooded Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eAston Martin\u003c\/td\u003e\n\u003ctd\u003eDB11\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eAston Martin\u003c\/td\u003e\n\u003ctd\u003eDB11\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018\u003c\/td\u003e\n\u003ctd\u003eAston Martin\u003c\/td\u003e\n\u003ctd\u003eDB11\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.2 V12; OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 850\/RC 160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008\u003c\/td\u003e\n\u003ctd\u003eAston Martin\u003c\/td\u003e\n\u003ctd\u003eDB9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eAston Martin\u003c\/td\u003e\n\u003ctd\u003eDBS\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eAston Martin\u003c\/td\u003e\n\u003ctd\u003eDBS\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2020\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2012\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2020\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 allroad\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2016\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 allroad\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 allroad\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 allroad\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2021\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2012\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2021\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA4 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2013\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2017\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2012, 2018–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006–2012\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA6 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2005–2014\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA6 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA6 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA7 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2014\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA7 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA7 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA8 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016, 2019–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA8 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003–2007, 2010–2015, 2017–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eA8 Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2016\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eallroad\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eallroad\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ5 PHEV\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2015, 2017–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2023, 2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eQ8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018, 2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eR8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eR8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS Q8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS Q8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS Q8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2008\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2015, 2018–2019\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2015, 2017–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eRS7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2015\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016, 2018–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016, 2018–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2016\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2010, 2016–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011, 2013–2015\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2017\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2018\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0K, PR Codes denote factory installed options for the vehicle, OE battery is EFB (Enhanced Flooded Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 760\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003, 2007, 2013–2018, 2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eS8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2017, 2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2015\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J2D, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 48, minimum vehicle requirement: CCA 680\/RC 120, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ5 Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eSQ8 e-tron Sportback\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016, 2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eTT Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eTT Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eTT RS Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2022\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eTT RS Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2023\u003c\/td\u003e\n\u003ctd\u003eAudi\u003c\/td\u003e\n\u003ctd\u003eTTS Quattro\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBentley\u003c\/td\u003e\n\u003ctd\u003eContinental\u003c\/td\u003e\n\u003ctd\u003eAuxiliary\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBentley\u003c\/td\u003e\n\u003ctd\u003eContinental\u003c\/td\u003e\n\u003ctd\u003eAuxiliary\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2011\u003c\/td\u003e\n\u003ctd\u003eBentley\u003c\/td\u003e\n\u003ctd\u003eContinental\u003c\/td\u003e\n\u003ctd\u003eLeft\u003c\/td\u003e\n\u003ctd\u003eMain Battery, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBentley\u003c\/td\u003e\n\u003ctd\u003eMulsanne\u003c\/td\u003e\n\u003ctd\u003eAuxiliary\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003eBentley\u003c\/td\u003e\n\u003ctd\u003eMulsanne\u003c\/td\u003e\n\u003ctd\u003eLeft\u003c\/td\u003e\n\u003ctd\u003eMain Battery, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e1 Series M\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e228i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e228i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e228i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e230i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e230i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e230i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e230i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2021, 2023–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e230i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e320i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013, 2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e320i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e320i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e320i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013, 2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e320i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e320i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e320i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003–2006\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e325Ci\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, SULEV, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2004\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e325i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2002–2003\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e325i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, SULEV, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328d xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328d xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328d xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 720\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2008\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 720\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e328i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018, 2021–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330e xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e330i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 720\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e335is\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 720\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e340i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e340i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e340i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e428i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e428i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e428i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e428i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e428i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e428i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e428i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2020\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e430i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e435i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e435i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e435i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e435i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e435i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e435i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e440i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e440i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e440i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e440i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e528i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e530e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e530e xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2020\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e530i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2020\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e530i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535d xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011, 2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e535i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e540d xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e540i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 720\/RC 130, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e540i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e540i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e540i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i GT xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e550i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Best performance estimate, Battery is vented to outside of vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Vehicle computer system must be reset, contact your service specialist, AGM Valve Regulated Lead Acid VRLA  is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Best performance estimate, Battery is vented to outside of vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Vehicle computer system must be reset, contact your service specialist, AGM Valve Regulated Lead Acid VRLA  is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, Vehicle computer system must be reset, contact your service specialist, AGM Valve Regulated Lead Acid VRLA  is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e640i xDrive Gran Turismo\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Best performance estimate, Battery is vented to outside of vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Vehicle computer system must be reset, contact your service specialist, AGM Valve Regulated Lead Acid VRLA  is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Best performance estimate, Battery is vented to outside of vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Vehicle computer system must be reset, contact your service specialist, AGM Valve Regulated Lead Acid VRLA  is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e650i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740e xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 600\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740e xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740Ld xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e740Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2004–2005\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e745i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2002–2003\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e745i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2004–2005\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e745Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2002–2003\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e745Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006–2008\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011, 2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011, 2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006–2009\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011, 2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e750Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2004–2005\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e760i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, Vehicle computer system must be reset, contact your service specialist\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003–2005\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e760Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, Vehicle computer system must be reset, contact your service specialist\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e760Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e760Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003e760Li\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eActiveHybrid 7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Hybrid, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7 xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7 xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Hybrid, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7 xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7L\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7L\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Hybrid, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7L\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7L xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7L xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Hybrid, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eAlpina B7L xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eK1600GT\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM Valve Regulated Lead Battery , CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid VRLA  is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM235i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBody Type: Convertible; Vehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM235i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM235i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBody Type: Coupe; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM235i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBody Type: Convertible; When replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM235i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM235i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBody Type: Convertible; When replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM240i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM240i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM240i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM340i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM440i\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM440i Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM440i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM440i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022, 2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM440i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSold Country: United States; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM550i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, When replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM6 Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM760i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM760Li xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM850i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM850i xDrive\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eM850i xDrive Gran Coupe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 720\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007, 2009\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Optional, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2012, 2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: N55B30A; Vehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: N20B20A; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eFuel Type: Diesel; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015, 2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Vehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2022\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015, 2018\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Sold Country: United States; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.5 V8; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eFuel Type: Diesel; Sold Country: United States; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eFuel Type: Gas; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eFuel Type: PLUG-IN HYBRID EV-GAS (PHEV); Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2012\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2011\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 4.4 V8; Fuel Type: Gas; Vehicle computer system must be reset, contact your service specialist, Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2015\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eX7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eZ4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eBMW\u003c\/td\u003e\n\u003ctd\u003eZ4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2020\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eCT6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOriginal equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eCT6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Fuel Type: Gas; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eCT6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eCT6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.6 V6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eCT6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOriginal equipment replacement, Include KL9 Start Stop, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOriginal equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024, 2026–2027\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOriginal Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: L87; Engine VIN: L; Engine: 6.2 V8; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: LM2; Engine VIN: T; Engine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: LT4; Engine VIN: 6; Engine: 6.2 V8; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade ESV\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOriginal equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024, 2026–2027\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade ESV\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOriginal Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade ESV\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: L87; Engine VIN: L; Engine: 6.2 V8; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade ESV\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: LM2; Engine VIN: T; Engine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade ESV\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine ID: LT4; Engine VIN: 6; Engine: 6.2 V8; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021\u003c\/td\u003e\n\u003ctd\u003eCadillac\u003c\/td\u003e\n\u003ctd\u003eEscalade ESV\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2022\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eColorado\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.8 L4; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eImpala\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOriginal equipment replacement, Include KL9 Start Stop, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2015\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eMalibu\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.5 L4; Original equipment replacement, Include KL9 Start Stop, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eSilverado 1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024–2026\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eSilverado 1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eSilverado 1500 LTD\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eSuburban\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024–2027\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eSuburban\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eTahoe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024–2027\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eTahoe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2026–2027\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eTahoe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: Commercial; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eTahoe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: PPV; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024–2027\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eTahoe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: PPV; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eTahoe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: SSV; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024\u003c\/td\u003e\n\u003ctd\u003eChevrolet\u003c\/td\u003e\n\u003ctd\u003eTahoe\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: SSV; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2023\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: Enforcer; BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eCharger\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: Pursuit; BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.6 V6; Sub Model: Special Service; BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.7 V8; Sub Model: Special Service; BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2020\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: Special Service; BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.7 V8; Sub Model: Special Service; OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.7 V8; OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSub Model: Special Service; OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.6 V6; With Special Service Package, BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eDodge\u003c\/td\u003e\n\u003ctd\u003eDurango\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.7 V8; With Special Service Package, BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2014\u003c\/td\u003e\n\u003ctd\u003eFerrari\u003c\/td\u003e\n\u003ctd\u003eCalifornia\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Include Start Stop Technology, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eFord\u003c\/td\u003e\n\u003ctd\u003eExplorer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Optional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eFord\u003c\/td\u003e\n\u003ctd\u003eF-150\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019, 2021\u003c\/td\u003e\n\u003ctd\u003eFord\u003c\/td\u003e\n\u003ctd\u003eF-150\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eFord\u003c\/td\u003e\n\u003ctd\u003ePolice Interceptor Utility\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.3 V6; BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2025\u003c\/td\u003e\n\u003ctd\u003eFord\u003c\/td\u003e\n\u003ctd\u003ePolice Interceptor Utility\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Optional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eFord\u003c\/td\u003e\n\u003ctd\u003ePolice Interceptor Utility\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2021\u003c\/td\u003e\n\u003ctd\u003eFreightliner\u003c\/td\u003e\n\u003ctd\u003eSprinter 4500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eTwo batteries may be required, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2022\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eCanyon\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.8 L4; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eSierra 1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024–2026\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eSierra 1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eSierra 1500 Limited\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eYukon\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024–2027\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eYukon\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eYukon XL\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original equipment replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024–2027\u003c\/td\u003e\n\u003ctd\u003eGMC\u003c\/td\u003e\n\u003ctd\u003eYukon XL\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Original Equipment Replacement, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eF-Pace\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWith Park Heater or H.D Battery, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eF-Pace\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWith Park Heater or Heavy Duty Battery, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eF-Type\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 900\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015, 2017\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eF-Type\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eF-Type\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2015\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eXF\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; BCI 49, minimum vehicle requirement: CCA 900\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2015\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eXF\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.0 V8; BCI 49, minimum vehicle requirement: CCA 900\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eXJ\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 900\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eJaguar\u003c\/td\u003e\n\u003ctd\u003eXJ\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Cherokee\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2020\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Cherokee\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Cherokee\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Cherokee\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.6 V6; Optional, BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Cherokee\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.7 V8; Optional, BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Cherokee\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 6.4 V8; Optional, BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2023\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Wagoneer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 6.4 V8; BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eGrand Wagoneer L\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eWagoneer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eJeep\u003c\/td\u003e\n\u003ctd\u003eWagoneer\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.7 V8; BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eKia\u003c\/td\u003e\n\u003ctd\u003eSedona\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eR-MDPS, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2019\u003c\/td\u003e\n\u003ctd\u003eKia\u003c\/td\u003e\n\u003ctd\u003eSedona\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eR-MDPS, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eKia\u003c\/td\u003e\n\u003ctd\u003eStinger\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.3 V6; BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eKia\u003c\/td\u003e\n\u003ctd\u003eStinger\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.3 V6; OE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 850\/RC 160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDefender 110\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDefender 110\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDefender 130\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDefender 130\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Sold Country: United States; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDefender 90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDiscovery\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDiscovery\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDiscovery\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Fuel Type: MILD HYBRID EV-GAS (MHEV); Sold Country: Canada; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDiscovery\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; Fuel Type: MILD HYBRID EV-GAS (MHEV); Sold Country: United States; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2022\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eDiscovery\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; Fuel Type: MILD HYBRID EV-GAS (MHEV); CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.0 V8; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAspiration: Turbo; Exclude Cold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Sold Country: United States; Exclude Cold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Exclude Cold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVIN BA349791 up, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2015\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAspiration: Super-Chrg; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAspiration: Turbo\/Supercharged; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eFuel Type: PLUG-IN HYBRID EV-GAS (PHEV); CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 L6; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 5.0 V8; CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAspiration: Turbo; Exclude Cold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eFuel Type: Diesel; Exclude Cold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Sport\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Exclude Cold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Velar\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eLand Rover\u003c\/td\u003e\n\u003ctd\u003eRange Rover Velar\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCold Climate, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eLincoln\u003c\/td\u003e\n\u003ctd\u003eAviator\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2024\u003c\/td\u003e\n\u003ctd\u003eLincoln\u003c\/td\u003e\n\u003ctd\u003eNavigator\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eLincoln\u003c\/td\u003e\n\u003ctd\u003eNavigator\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2019\u003c\/td\u003e\n\u003ctd\u003eMaserati\u003c\/td\u003e\n\u003ctd\u003eGhibli\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2019\u003c\/td\u003e\n\u003ctd\u003eMaserati\u003c\/td\u003e\n\u003ctd\u003eGranTurismo\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eMaserati\u003c\/td\u003e\n\u003ctd\u003eLevante\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2011\u003c\/td\u003e\n\u003ctd\u003eMaserati\u003c\/td\u003e\n\u003ctd\u003eQuattroporte\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2019\u003c\/td\u003e\n\u003ctd\u003eMaserati\u003c\/td\u003e\n\u003ctd\u003eQuattroporte\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003–2004, 2006–2012\u003c\/td\u003e\n\u003ctd\u003eMaybach\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003–2004, 2006–2012\u003c\/td\u003e\n\u003ctd\u003eMaybach\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eAMG GT 63\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2021\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eAMG GT 63\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eAMG GT 63 S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2021\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eAMG GT 63 S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eC300\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eC350e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2021\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eC63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eC63 AMG S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eC63 AMG S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eC63 AMG S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL55 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 850\/RC 160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2010\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003, 2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011, 2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2010\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCL65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS55 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, Auxiliary battery required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2011\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2011\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 720\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014, 2017–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS63 AMG S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eCLS63 AMG S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE250\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE300\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015, 2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE300\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2009\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE320\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE320\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, Auxiliary battery required, use ATX14BS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006–2010\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.5 V6; O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Optional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE43 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2020\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE55 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, Auxiliary battery required, use ATX14BS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2009\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2009\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eE63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eG550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2022\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eG550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eG550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSold Country: United States; O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eG550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eG63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eG63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eG65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2011, 2013, 2015–2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2011, 2013, 2015–2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2011, 2015–2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE300d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE300d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE350d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE43 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE450 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE53 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE53 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE550e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE63 AMG S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLE63 AMG S\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLS350d\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLS450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLS450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eGLS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eMaybach S550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 800\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eMaybach S600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016–2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eMetris\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eML250\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006–2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eML350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eML350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eML350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eML400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2009\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eR320\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2013\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eR350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eR63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1994–1999\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS320\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 825\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1995\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 760\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1994\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 825\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS350\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1994–1999\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS420\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 825\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS430\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000–2005\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS430\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 825\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2009, 2011\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2002–2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1994–2001\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 760\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS55 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2001–2002, 2004–2005\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS55 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 825\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2009, 2011–2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010, 2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS550e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2020\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS560\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2020\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS560e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS580\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS580e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS580e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eSold Country: United States; O.E. manufacturer used various size batteries in production. Carefully size to fit, Electrical System Battery, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003–2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1994–1999\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 825\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS600\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2008–2010, 2018–2020\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eO.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2014\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2006\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007–2012\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOn-Board Electrical System Battery, OE Battery is AGM (Valve Regulated Lead Battery), Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2017\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eS65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, OE Battery is AGM (Valve Regulated Lead Battery), CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL400\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL550\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOE Battery is AGM (Valve Regulated Lead Battery), BCI 49, minimum vehicle requirement: CCA 800\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2019\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL63 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013–2018\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSL65 AMG\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSprinter 1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2022, 2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSprinter 2500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSprinter 3500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2024\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSprinter 3500XD\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 690\/RC 130, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2021\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSprinter 4500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eTwo batteries may be required, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2022–2023\u003c\/td\u003e\n\u003ctd\u003eMercedes-Benz\u003c\/td\u003e\n\u003ctd\u003eSprinter 4500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Two batteries may be required, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003e911\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR Codes denote factory installed options for the vehicle, PR-200, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2012–2016\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003eBoxster\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR Codes denote factory installed options for the vehicle, PR-200, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2011–2013\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003eCayenne\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003ePR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2003–2006\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003eCayenne\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003ePR-J2C, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2018\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003eCayenne\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2016\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003eCayman\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR Codes denote factory installed options for the vehicle, PR-200, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015–2019\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003eMacan\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003eMacan\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2016\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003ePanamera\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR Codes denote factory installed options for the vehicle, PR-200, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2022\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003ePanamera\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003ePanamera\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.9 V6; Vehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003ePanamera\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Sold Country: United States; Vehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003ePorsche\u003c\/td\u003e\n\u003ctd\u003ePanamera\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 4.0 V8; Vehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020\u003c\/td\u003e\n\u003ctd\u003eRam\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; BCI 49, minimum vehicle requirement: CCA 800\/RC 130, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2023\u003c\/td\u003e\n\u003ctd\u003eRam\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; BCI 49, minimum vehicle requirement: CCA 800\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014–2018\u003c\/td\u003e\n\u003ctd\u003eRam\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; Vehicle computer system must be reset, contact your service specialist, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019\u003c\/td\u003e\n\u003ctd\u003eRam\u003c\/td\u003e\n\u003ctd\u003e1500 Classic\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.0 V6; BCI 49, minimum vehicle requirement: CCA 800\/RC 130, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eRolls-Royce\u003c\/td\u003e\n\u003ctd\u003eGhost\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2010–2012, 2015\u003c\/td\u003e\n\u003ctd\u003eRolls-Royce\u003c\/td\u003e\n\u003ctd\u003eGhost\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eRolls-Royce\u003c\/td\u003e\n\u003ctd\u003eGhost\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eWhen replacing the battery in an iDrive equipped vehicle, resetting of the system may be required at a dealership, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2004–2014\u003c\/td\u003e\n\u003ctd\u003eRolls-Royce\u003c\/td\u003e\n\u003ctd\u003ePhantom\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2014\u003c\/td\u003e\n\u003ctd\u003eRolls-Royce\u003c\/td\u003e\n\u003ctd\u003eWraith\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBest performance estimate, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2015\u003c\/td\u003e\n\u003ctd\u003eRolls-Royce\u003c\/td\u003e\n\u003ctd\u003eWraith\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 900\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2024\u003c\/td\u003e\n\u003ctd\u003eToyota\u003c\/td\u003e\n\u003ctd\u003eGR Supra\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 2.0 L4; BCI 49, minimum vehicle requirement: CCA 850\/RC 160, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2019–2022\u003c\/td\u003e\n\u003ctd\u003eVolkswagen\u003c\/td\u003e\n\u003ctd\u003eArteon\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2009–2010\u003c\/td\u003e\n\u003ctd\u003eVolkswagen\u003c\/td\u003e\n\u003ctd\u003ePassat\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, CCA listed is an EN rating, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2004–2006\u003c\/td\u003e\n\u003ctd\u003eVolkswagen\u003c\/td\u003e\n\u003ctd\u003ePhaeton\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2004, 2006, 2008–2017\u003c\/td\u003e\n\u003ctd\u003eVolkswagen\u003c\/td\u003e\n\u003ctd\u003eTouareg\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2007\u003c\/td\u003e\n\u003ctd\u003eVolkswagen\u003c\/td\u003e\n\u003ctd\u003eTouareg\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAspiration: Normal; Vehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2005\u003c\/td\u003e\n\u003ctd\u003eVolkswagen\u003c\/td\u003e\n\u003ctd\u003eTouareg\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 3.2 V6; Vehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2005\u003c\/td\u003e\n\u003ctd\u003eVolkswagen\u003c\/td\u003e\n\u003ctd\u003eTouareg\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEngine: 4.2 V8; Vehicle computer system must be reset, contact your service specialist, PR-J0B, PR Codes denote factory installed options for the vehicle, O.E. manufacturer used various size batteries in production. Carefully size to fit, Best performance estimate, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2021–2022\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eS90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCan Variant Code CS04, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eS90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eOptional, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eV90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS04 or CS0E, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2021\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eV90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS0E or CS04, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017–2019\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eV90 Cross Country\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS04 or CS0E, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eV90 Cross Country\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS0E or CS04, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eXC60\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS02, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eXC60\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS02, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eXC90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eEarly, BCI 49, minimum vehicle requirement: CCA 760\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2018–2019\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eXC90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS04 or CS0E, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2020–2022\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eXC90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS04 or CS0E, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) battery is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2017\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eXC90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS04, O.E. manufacturer used various size batteries in production. Carefully size to fit, BCI 49, minimum vehicle requirement: CCA 850\/RC 150, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2016\u003c\/td\u003e\n\u003ctd\u003eVolvo\u003c\/td\u003e\n\u003ctd\u003eXC90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVariant Code CS04, O.E. manufacturer used various size batteries in production. Carefully size to fit, Late, BCI 49, minimum vehicle requirement: CCA 850\/RC 160, Battery is vented to outside of vehicle, AGM Valve Regulated Lead Acid (VRLA) is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cp style=\"font-size:12px\"\u003eSource: supplier-verified applications for ACDelco Gold 49AGM. A vehicle not listed is not confirmed compatible.\u003c\/p\u003e\u003c\/section\u003e\u003c!-- XPART_AI_AUTO_FITMENT_END --\u003e\n\u003c\/div\u003e","brand":"ACDelco Gold","offers":[{"title":"OEM Genuine","offer_id":53516870582561,"sku":"P1005-180455","price":526.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0897\/7783\/2225\/files\/wam_0cadcc15-3006-400e-a282-09a672131229.jpg?v=1789570102","url":"https:\/\/xpartsupply.com\/en-us\/products\/49agm-battery-auto-part","provider":"XPart Supply Ltd.","version":"1.0","type":"link"}