{"product_id":"embraco-compressor-start-relay-capacitor-513605014-restore-refrigerator-compressor-start","title":"Embraco Start Relay \u0026 Capacitor 513605014 — Restore Refrigerator Compressor Start","description":"\u003cstyle\u003e\n.hero-banner{\nposition:relative;\noverflow:hidden;\nbackground:\nlinear-gradient(135deg,rgba(0,0,0,.86) 55%,rgba(0,0,0,.45)),\nurl('https:\/\/cdn.shopify.com\/s\/files\/1\/0897\/7783\/2225\/files\/4444444444444444.png?v=1777040489') center\/cover no-repeat;\npadding:44px 34px;\nborder-radius:12px;\nmargin:0 0 28px;\ncolor:#fff;\nbox-shadow:0 10px 30px rgba(0,0,0,.25);\n}\n.hero-banner:before{\ncontent:'';\nposition:absolute;\ninset:0;\nbackground:radial-gradient(circle at center,rgba(0,153,255,.20),transparent 65%);\nanimation:pulse 5s infinite;\n}\n.hero-banner\u003e*{\nposition:relative;\nz-index:2;\n}\n.hero-banner h2{\nmargin:0 0 8px;\nfont-size:1.85em;\nfont-weight:900;\nletter-spacing:.2px;\nline-height:1.1;\n}\n.label{\ndisplay:inline-block;\nbackground:#c8a400;\ncolor:#000;\nfont-size:.72em;\nfont-weight:900;\ntext-transform:uppercase;\nletter-spacing:1px;\npadding:5px 12px;\nborder-radius:999px;\nmargin-bottom:12px;\n}\n.hero-specs{\ndisplay:flex;\nflex-wrap:wrap;\ngap:8px;\nmargin-top:15px;\n}\n.hero-specs span{\nbackground:rgba(255,255,255,.14);\nborder:1px solid rgba(255,255,255,.25);\nborder-radius:999px;\npadding:7px 13px;\nfont-size:.82em;\nfont-weight:800;\n}\n.pro-tip{\nposition:relative;\noverflow:hidden;\nbackground:#1a1a2e;\nborder-left:5px solid #c8a400;\npadding:16px 20px;\nborder-radius:8px;\nmargin:24px 0;\ncolor:#f0f0f0;\nfont-size:.95em;\nline-height:1.6;\n}\n.pro-tip strong{\ncolor:#c8a400;\n}\n.upsell-box{\nbackground:#ffecd1;\nborder-left:5px solid #ff9800;\npadding:14px 18px;\nmargin:20px 0;\nborder-radius:8px;\n}\n@keyframes pulse{\n50%{opacity:.85}\n}\n\u003c\/style\u003e\n\n\u003c!-- HERO BANNER --\u003e\n\u003cdiv class=\"hero-banner\"\u003e\n  \u003cdiv class=\"label\"\u003eOEM REPLACEMENT PART\u003c\/div\u003e\n  \u003ch2\u003eEmbraco Start Relay \u0026amp; Capacitor 513605014 — Restore Refrigerator Compressor Start\u003c\/h2\u003e\n  \u003cdiv class=\"hero-specs\"\u003e\n    \u003cspan\u003ePart# 513605014\u003c\/span\u003e\n    \u003cspan\u003eReplaces CK513605014\u003c\/span\u003e\n    \u003cspan\u003eFits Embraco TSD2\u003c\/span\u003e\n    \u003cspan\u003e1\/4\" Terminal\u003c\/span\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- H1 --\u003e\n\u003ch1\u003eRefrigerator Compressor Won't Start? Start Relay \u0026amp; Capacitor 513605014 – Fix Compressor Failure Fast\u003c\/h1\u003e\n\n\u003c!-- INTRO --\u003e\n\u003cp\u003e\n\u003cstrong\u003eIf your refrigerator compressor clicks but won't run, or the fridge has stopped cooling entirely, the start relay and capacitor are the most common cause.\u003c\/strong\u003e\nIn most Embraco TSD2 compressor-equipped refrigerators, this is caused by a failed start relay or run capacitor.\nWhen it fails, the compressor cannot generate the torque needed to start — leaving the fridge warm while fans continue to run normally.\n\u003cstrong\u003e⚡ Common failure point in Embraco-built refrigerator compressors.\u003c\/strong\u003e\n\u003cstrong\u003ePart 513605014\u003c\/strong\u003e is the genuine OEM replacement that restores full compressor start and run performance in one kit.\n\u003c\/p\u003e\n\n\u003c!-- IS THIS THE RIGHT PART --\u003e\n\u003ch3\u003e❓ Is This the Right Part?\u003c\/h3\u003e\n\u003cp\u003eThis is the correct fix if ALL of the following are true:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e✔ Refrigerator powers on and fans run normally\u003c\/li\u003e\n\u003cli\u003e✔ Evaporator fan and condenser fan operate correctly\u003c\/li\u003e\n\u003cli\u003e✔ Power supply and outlet confirmed OK\u003c\/li\u003e\n\u003cli\u003e✔ ONLY problem is compressor clicks on then immediately shuts off, or won't start at all\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNot sure? \u003ca href=\"\/pages\/contact\"\u003eSend us your model number\u003c\/a\u003e — we'll confirm before you order.\u003c\/p\u003e\n\n\u003c!-- COMMON SYMPTOMS --\u003e\n\u003ch3\u003e🔧 Common Symptoms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor clicks on but immediately shuts off (classic start relay failure)\u003c\/li\u003e\n\u003cli\u003eRefrigerator not cooling — compressor won't run despite fans operating\u003c\/li\u003e\n\u003cli\u003eHumming or buzzing from the compressor area with no start\u003c\/li\u003e\n\u003cli\u003eCompressor runs briefly then trips off on thermal overload\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e✔ If these symptoms match, this is the most likely failed component in the system.\u003c\/p\u003e\n\u003cp\u003e✔ In most cases, replacing this start relay and capacitor kit restores normal operation immediately.\u003c\/p\u003e\n\n\u003c!-- PART DETAILS --\u003e\n\u003ch3\u003e📦 Part Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 513605014\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Compressor Start Relay \u0026amp; Run Capacitor Kit — Heavy Duty, 1\/4\" Push-On Terminal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e CK513605014\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrands:\u003c\/strong\u003e Embraco, TSD2 Series Compressors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- UPSELL --\u003e\n\u003cdiv class=\"upsell-box\"\u003e\n\u003cstrong\u003e⚠️ Recommended While Repairing:\u003c\/strong\u003e\u003cbr\u003e\nAlso inspect the \u003cstrong\u003ethermal overload protector\u003c\/strong\u003e on the compressor. A failed overload will trip the compressor even after a new relay is installed — catching both failures in one service call saves a costly return visit. If the overload rattles or shows open continuity, replace it at the same time.\n\u003c\/div\u003e\n\n\u003c!-- INSTALLATION --\u003e\n\u003ch3\u003e⚙️ Installation\u003c\/h3\u003e\n\u003cp\u003e\n\u003cstrong\u003eSkill Level: Moderate — 15–30 minutes.\u003c\/strong\u003e\nDisconnect power before servicing. Locate the compressor at the rear bottom of the refrigerator, remove the existing relay and capacitor from the compressor terminals, and install the new kit onto the 1\/4\" push-on terminals — ensure firm seating on both connections. Restore power and verify the compressor starts and runs normally.\n\u003c\/p\u003e\n\n\u003c!-- COMPATIBLE MODELS --\u003e\n\u003ch3\u003e✓ Compatible Models\u003c\/h3\u003e\n\u003cp\u003e\nConfirmed compatible with Embraco TSD2 series compressor-equipped refrigerators using the 513605014 \/ CK513605014 start relay and capacitor kit. Fits units with 1\/4\" push-on terminal compressors.\n\u003ca href=\"\/pages\/contact\"\u003eContact us to verify your model number\u003c\/a\u003e before ordering.\n\u003c\/p\u003e\n\n\u003c!-- PRO TIP --\u003e\n\u003ch3\u003e💡 Pro Tip\u003c\/h3\u003e\n\u003cdiv class=\"pro-tip\"\u003e\n\u003cstrong\u003eRattle Test Before You Order:\u003c\/strong\u003e\u003cbr\u003e\nRemove the existing start relay from the compressor and shake it. If you hear a rattle, the internal PTC element has failed — this confirms the relay is the cause of the no-start condition. A good relay is silent when shaken. This simple test takes 30 seconds and eliminates guesswork before committing to a repair.\n\u003c\/div\u003e","brand":"Embraco","offers":[{"title":"Default Title","offer_id":52798757110049,"sku":"513605014","price":92.5,"currency_code":"CAD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0897\/7783\/2225\/files\/Embraco_Compressor_Start_Relay_Capacitor_513605014_Restore_Refrigerator_Compressor_Start.png?v=1780513347","url":"https:\/\/xpartsupply.com\/products\/embraco-compressor-start-relay-capacitor-513605014-restore-refrigerator-compressor-start","provider":"XPart Supply Ltd.","version":"1.0","type":"link"}