Samsung + LG Dryer Error Codes
Brand,Appliance Type,Error Code,Error Description,What the Customer Experiences,Common Causes,Most Likely Failed Part,Secondary Possible Parts,Part Category,Troubleshooting Steps,Reset Possible,DIY Skill Level,Estimated Repair Time,Safety Notes,XPart Supply Search Link,SEO Keywords,Author
Samsung,Dryer,d80,Restricted airflow,Clothes take too long to dry,Blocked vent lint buildup,Vent duct kit,Blower housing lint screen,Vent System,Clean entire vent path,Yes,Beginner,30–45 min,Fire hazard if ignored,https://xpartsupply.com/search?q=Samsung+dryer+vent+kit,samsung dryer d80 error,XPart Supply
Samsung,Dryer,d90,Severe airflow restriction,Dryer shuts down early,Crushed or clogged vent,Vent duct kit,Blower wheel,Vent System,Inspect vent routing clean lint,Yes,Beginner,30–45 min,Fire risk high,https://xpartsupply.com/search?q=Samsung+dryer+vent+duct,samsung dryer d90 error,XPart Supply
Samsung,Dryer,HE,Heating error,No heat during cycle,Heating element failure,Heating element,Thermal fuse,Heating System,Test heater resistance replace if open,Yes,Intermediate,45–60 min,High voltage present,https://xpartsupply.com/search?q=Samsung+dryer+heating+element,samsung dryer HE error,XPart Supply
Samsung,Dryer,tE,Temperature sensor error,Dryer stops mid-cycle,Thermistor failure,Temperature sensor,Thermal fuse,Sensor System,Test thermistor replace if faulty,Yes,Intermediate,45 min,Let dryer cool first,https://xpartsupply.com/search?q=Samsung+dryer+thermistor,samsung dryer tE error,XPart Supply
Samsung,Dryer,dE,Door error,Dryer will not start,Door switch failure,Door switch,Door latch,Door System,Test switch continuity replace,Yes,Beginner,20–30 min,Glass door fragile,https://xpartsupply.com/search?q=Samsung+dryer+door+switch,samsung dryer dE error,XPart Supply
Samsung,Dryer,PF,Power failure,Cycle interrupted,Power outage loose cord,Power cord,Terminal block,Electrical,Restore power restart cycle,Yes,Beginner,5–10 min,Ensure proper grounding,https://xpartsupply.com/search?q=Samsung+dryer+power+cord,samsung dryer PF error,XPart Supply
Samsung,Dryer,FC,Communication fault,Dryer unresponsive,Control board communication failure,Main control board,UI board,Electronics,Reset power inspect wiring,Yes,Advanced,60–90 min,Static sensitive parts,https://xpartsupply.com/search?q=Samsung+dryer+control+board,samsung dryer FC error,XPart Supply
Samsung,Dryer,E3,Overheating detected,Dryer stops for safety,Blocked vent thermostat failure,High-limit thermostat,Thermal fuse,Safety Controls,Clean vent test thermostat,Yes,Intermediate,45–60 min,Fire prevention system,https://xpartsupply.com/search?q=Samsung+dryer+high+limit+thermostat,samsung dryer E3 error,XPart Supply
LG,Dryer,d80,Airflow restriction,Dryer runs but clothes damp,Blocked vent lint buildup,Vent duct kit,Blower housing lint screen,Vent System,Clean vent system completely,Yes,Beginner,30–45 min,Fire hazard,https://xpartsupply.com/search?q=LG+dryer+vent+kit,lg dryer d80 error,XPart Supply
LG,Dryer,d90,Severe vent blockage,Dryer shuts down early,Crushed vent or blockage,Vent duct kit,Blower wheel,Vent System,Inspect vent routing clean lint,Yes,Beginner,30–45 min,High fire risk,https://xpartsupply.com/search?q=LG+dryer+vent+duct,lg dryer d90 error,XPart Supply
LG,Dryer,HE,Heating error,No heat produced,Heating element failure,Heating element,Thermal fuse,Heating System,Test heater continuity replace if open,Yes,Intermediate,45–60 min,High voltage inside,https://xpartsupply.com/search?q=LG+dryer+heating+element,lg dryer HE error,XPart Supply
LG,Dryer,tE1,Temperature sensor fault,Dryer stops unexpectedly,Thermistor failure,Temperature sensor,Thermal fuse,Sensor System,Test thermistor resistance,Yes,Intermediate,45 min,Allow cooling time,https://xpartsupply.com/search?q=LG+dryer+thermistor,lg dryer tE1 error,XPart Supply
LG,Dryer,dE1,Door switch error,Dryer will not start,Door switch or latch failure,Door switch,Door latch,Door System,Replace faulty switch,Yes,Beginner,20–30 min,Handle glass carefully,https://xpartsupply.com/search?q=LG+dryer+door+switch,lg dryer dE1 error,XPart Supply
LG,Dryer,PS,Power supply error,Dryer won’t power on,Loose cord terminal block,Terminal block,Power cord,Electrical,Inspect terminals tighten connections,Yes,Beginner,20–30 min,Disconnect power first,https://xpartsupply.com/search?q=LG+dryer+terminal+block,lg dryer PS error,XPart Supply
LG,Dryer,HS,Humidity sensor error,Dryer overdrys or underdries,Failed moisture sensor,Moisture sensor bars,Control board,Sensor System,Clean or replace sensor bars,Yes,Beginner,20–30 min,Avoid sharp edges,https://xpartsupply.com/search?q=LG+dryer+moisture+sensor,lg dryer HS error,XPart Supply
LG,Dryer,E6,Motor error,Dryer drum not turning,Motor or centrifugal switch failure,Drive motor,Motor relay,Motor System,Test motor windings replace if faulty,No,Advanced,60–90 min,Heavy motor assembly,https://xpartsupply.com/search?q=LG+dryer+motor,lg dryer E6 error,XPart Supply
- Choosing a selection results in a full page refresh.