Genuine OEM Replacement Part
Danby 11002017000725 Dehumidifier AC Shaded Pole Fan Motor – Genuine OEM Replacement
Part# 11002017000725
Fits DPA120 · DPA140 Series
AC Shaded Pole — Single Phase
Ships from Canada 🇨🇦
11002017000725 Danby Dehumidifier Fan Motor – Unit Stops Pulling Moisture When This Motor Fails
When the shaded pole fan motor fails in your Danby dehumidifier, airflow through the evaporator coils stops — and without airflow, the unit can no longer pull moisture from the air. The result is a dehumidifier that runs but does nothing, or one that shuts off on a safety fault. Part 11002017000725 is the genuine OEM replacement motor that restores proper fan operation and gets your dehumidifier working again.
Symptoms of a Failed Dehumidifier Fan Motor
- Dehumidifier runs but humidity level in the room doesn’t drop
- No airflow from the unit — fan not spinning despite compressor running
- Unit shuts off shortly after starting (thermal overload / safety cutout)
- Humming or buzzing sound with no fan movement
- Coils freezing over due to lack of airflow across the evaporator
- Unit displays an error code or fault light related to fan or airflow
Part Details
-
OEM Part Number: 11002017000725
-
Part Type: AC Shaded Pole Fan Motor
-
Motor Type: Single-phase AC, continuous duty
-
Compatible Brands: Danby
-
Fits: DPA120 and DPA140 series dehumidifiers
-
Condition: Genuine OEM — New
-
Ships from: Canada 🇨🇦 — Fast domestic shipping
💡 Pro Tip — Check the Fan Blade & Capacitor Before Ordering:
Before replacing the motor, confirm the fan blade spins freely by hand with power disconnected. A seized blade or failed run capacitor can mimic a dead motor. If the blade is stiff or the capacitor tests bad, address those first — they’re cheaper fixes. If the blade spins freely but the motor still won’t run under power, this motor is your part.
Installation Notes
-
Skill Level: Intermediate — requires removing the outer cabinet and fan assembly bracket
-
Always unplug the dehumidifier before beginning any repair
- Note the wire harness routing and motor orientation before removal — shaded pole motors are directional
- Ensure the fan blade is fully seated and secured on the new motor shaft before reassembly
- Test run for 10–15 minutes and verify airflow and moisture collection before closing the cabinet
Compatible Models
DPA140HUB1WDD, DPA120BCCWDB, DPA120BEUWDB, DPA120HCB1WDB, DPA140CB1WDB