LG Microwave Door Interlock Switch 6600W1K001D, Fixes Microwave will not start
Genuine LG microwave door interlock/micro switch that interrupts microwave operation when the door is open and permits operation when the door is closed.
Confirm your full appliance model number before ordering.
Is This the Right Part?
✅ Cross Reference Information
Common Symptoms
- Microwave will not start
- Microwave does not heat
- Microwave continues running or does not shut off
Check Before Replacing
- With power disconnected, inspect the switch and terminals for visible burning or damage.
- A qualified technician can test switch continuity with a multimeter while actuating the switch.
- Microwave door-switch and shielding operation should be tested after replacement.
Pro Tip
Part Details
Installation Notes
- Disconnect electrical power before servicing.
- Microwave capacitors can retain dangerous voltage after unplugging; capacitor discharge and internal microwave service should be performed by a qualified technician.
- Door interlock and microwave shielding operation must be tested after installation.
Verified Compatible Models
58066291690, 62102, 62109, 62344, 62349, 62462, 62463, 62464, 62469, 63102, 63102301, 63109301, 721.61283100, 721.63654300, 721.63992302, 721.65002401, 721.66319500, 721.66462500, 721.80824500, 721.81043700, LCRM1240SB, LCRM1240ST, LCRT2010ST/00, LCS1112ST, LCS1112ST - CSBEAMZ, LCS1112ST - CSBELGA, LCS1112ST - CSBETAR, LMA1560SB, LMC2075BD, LMC2075ST, LMH1517CVST, LMHM2017ST/01, LMV1760ST, LMV1831BD, LMV2031BD, LMVH1711ST, LMVH1711ST - CSBELGA, LMVH1750SW, LMVM2033ST, LMVM2075ST, LRMP1270ST, LSMC3086SS, LTM9020W01
Fitment reminder: Match the complete appliance model number, including suffix or revision where applicable, before ordering.