OVEN DOES NOT HEAT BECAUSE GAS IS NOT BEING SUPPLIED TO THE BAKE OR BROIL BURNER
LG Range Oven gas valve MJX62571702, Fixes Oven does not heat because gas is not being supplied to the bake or broil burner
Genuine LG oven gas valve that controls gas flow to the bake and broil burners in an LG gas range.
Part MJX62571702LG
Guaranteed to Fit — or your money back.
Confirm your full appliance model number before ordering.
Confirm your full appliance model number before ordering.
Is This the Right Part?
Part NumberMJX62571702
ManufacturerLG
Appliance TypeRange
Part TypeOven gas valve
✅ Cross Reference Information
Current Part NumberMJX62571702
Common Symptoms
- Oven fails to heat or heats intermittently
- Bake or broil burner does not ignite despite a functioning ignition sequence
- Oven heating is delayed or temperature is not maintained
- F9 error may occur on some compatible LG ranges
Check Before Replacing
- Confirm the household gas shutoff valve and the range pressure-regulator valve are open, especially if the range was recently moved.
- Observe whether the oven igniter glows during a bake or broil call; a nonworking igniter can prevent heating without proving the gas valve is defective.
- If gas odor is present when the range is not operating, stop using the appliance, shut off the gas supply if safe, ventilate the area, and contact a qualified gas-appliance technician.
- Have a qualified technician verify the valve receives the proper control signal and that gas-line connections pass a leak check; do not bypass the valve or perform live gas testing.
Pro Tip
Do not condemn the gas valve from a no-heat symptom alone: verify the gas supply, regulator position, and igniter operation first, because those conditions can produce similar symptoms.
Part Details
Part NumberMJX62571702
Part TypeOven gas valve
ManufacturerLG
Appliance TypeRange
Primary FunctionControls gas flow to the oven bake and broil burners in an LG gas range, opening and closing as commanded to regulate oven heating.
Installation Notes
- Disconnect electrical power and shut off the gas supply before service.
- Gas-line connections must be leak-checked after installation with an appropriate non-corrosive leak-detection method.
- Because this component is part of a gas system, installation and service should be performed by a qualified or licensed gas-appliance technician.
- Do not reuse or alter gas connections, terminals, or wiring unless the model-specific service documentation explicitly permits it.
Verified Compatible Models
LRG4111ST, LRG4113ST, LRG4115ST, LSG4511BD, LSG4511ST, LSG4513BD, LSG4513ST, LSG4515BM, LSG4515ST, LSSG3016ST, LSSG3017BD, LSSG3019BD, LSSG3020BD, SKSGR480GS, UPSG3014ST
Fitment reminder: Match the complete appliance model number, including suffix or revision where applicable, before ordering.