AC Not Starting or Fan Not Spinning? Dual Run Capacitor 36-20-5-3744 — Fix Starting Failure Fast
If your air conditioner hums but won’t start, or the condenser fan spins slowly or only when manually pushed, a failed dual run capacitor is one of the most common causes. In most HVAC systems, the dual run capacitor supports both the compressor and the condenser fan motor from a single component. When it fails, one or both circuits lose the electrical boost needed to start and run. ⚡ Common failure point in residential central air and heat pump systems. Part 36-20-5-3744 is the Rotom OEM replacement that restores proper starting torque and run efficiency to both motor circuits.
🇺🇸 Matching U.S. Part Number: 36-20-5-3744
❓ Is This the Right Part?
This is the correct fix if ALL of the following are true:
- ✔ Unit powers on and the contactor is pulling in
- ✔ Electrical supply to the unit is confirmed OK
- ✔ Compressor or condenser fan motor is not seized
- ✔ Original capacitor is rated exactly 20/5MFD (not 20/4MFD, 20/7.5MFD or any other value)
- ✔ ONLY problem is the compressor or fan failing to start or running weakly
Not sure? Send us your model number — we’ll confirm before you order.
🔧 Common Symptoms
- AC hums but compressor won’t start
- Condenser fan spins slowly or only when manually pushed
- Unit short-cycles or shuts off shortly after starting
- Higher than normal energy bills with reduced cooling output
- Capacitor is visibly bulged, leaking, or measures out of spec
✔ If these symptoms match, this is the most likely failed component in the system.
✔ In most cases, replacing the dual run capacitor restores normal compressor and fan operation immediately.
📦 Part Details
- Part Number: 36-20-5-3744
- Type: Dual motor-run capacitor (compressor + condenser fan)
- Capacitance: 20/5 µF
- Voltage: 370/440 VAC
- Shape: Oval
- Width: 2.80 in
- Depth: 1.77 in
- Height: 3.15 in
- Terminals: C / FAN / HERM
- Features: Built-in pressure interrupter; UL and cUL recognized
- Brand/OEM: Rotom / AllTemp
- Direct Oval Equivalents: POCFD205, POCFD205A, TOCFD205, 12180, 12880, CD20+5X440, SFCAP20D5440, C4205L
Inspect the contactor at the same time. A worn or pitted contactor is a common companion failure in systems where the capacitor has failed — replacing both during the same service call prevents a repeat call-back.
⚙️ Installation
Skill Level: Moderate — 30 to 60 minutes. Disconnect and lock out power to the unit before opening the electrical compartment. Capacitors retain a hazardous charge after power is removed — discharge safely before handling. Match the terminal labels (C, FAN, HERM) exactly to the original wiring. Confirm oval mounting strap fit, cabinet clearance and terminal clearance before installing — dimensions vary between equivalent brands. Diagnosis and replacement should be completed by a qualified HVAC technician.
✓ Compatible Models
Compatibility for this capacitor is specification-based. Both capacitance values must remain exactly 20/5MFD, and the replacement voltage must equal or exceed the original equipment requirement. Confirm the oval shape and dimensions (2.80” × 1.77” × 3.15”) fit the mounting strap and cabinet clearance before ordering. Contact us to verify your model number before ordering.
💡 Pro Tip
The 36-20-5-3744 is an oval dual run capacitor. Round equivalents like 36-205R3744 carry the same 20/5MFD rating but require a different mounting strap. Both values must match exactly — a 20/4MFD or 20/7.5MFD capacitor is not a substitute even if the voltage and shape match. Always read the label on the old capacitor directly before ordering.
✅Compatibility & Cross Reference
Not sure about your model number? Call 1-877-899-7278 and we’ll help you confirm. All brand names are the property of their respective owners and are used for compatibility reference only.