Rotom Run HVAC Capacitor 36-60R3744 — Replace Failed 60 MFD 370/440V Round Capacitors
Rotom Run HVAC Capacitor 36-60R3744 — Replace Failed 60 MFD 370/440V Round Capacitors

Rotom HVAC Motor Run Capacitor 36-60R3744 — Round, 60MFD, 370/440V

Sale price
$41.99
Regular price
$45.77
You save
$3.78 (8%)

Frequently Bought Together

Confirm This Fits Your Model
Not sure where to find your model number? See guide →
SPECIFICATION-BASED REPLACEMENT

Rotom HVAC Motor Run Capacitor 36-60R3744 — Round, 60MFD, 370/440V

Part# 36-60R3744 60MFD 370/440 VAC Round — 2.17" dia × 5.12" H 🇺🇸 U.S. Part#: 36-60R3744

HVAC Motor Not Running Properly? Rotom Motor Run Capacitor 36-60R3744 — Restore 60MFD Motor Run Capacitance

A defective capacitor is one possible cause of motor starting or running problems in HVAC systems. The run capacitor maintains the phase shift required to keep the motor spinning efficiently under load. When it fails, the motor may hum, struggle to reach operating speed, run intermittently, or overheat.

⚡ Common service component in residential and light-commercial HVAC condensing and air-handling units.

Part 36-60R3744 is the Rotom specification-based replacement rated at 60MFD and 370/440 VAC that may restore motor-run support when testing confirms the original capacitor is defective and no related motor or electrical fault remains.

❓ Is This the Right Part?

Confirm the original 60MFD rating, voltage, shape and physical dimensions before ordering. This is the correct specification match if ALL of the following are true:

  • ✔ Your original capacitor is rated exactly 60MFD — capacitance must match exactly
  • ✔ Your original capacitor is rated 370V or 440V — a 440V replacement may replace a 370V original when capacitance matches; the reverse is not permitted
  • ✔ Configuration is a single-value run capacitor (not a dual-run)
  • ✔ Your mounting space accommodates a round body approximately 2.17" in diameter and 5.12" in height

Not sure? Send us your capacitor label specs — we’ll confirm before you order.

🔧 Common Symptoms of a Failed Motor-Run Capacitor

  • Fan or compressor motor hums but fails to start or reach operating speed
  • Motor starts then shuts off on thermal overload shortly after
  • Motor runs hot or draws higher-than-normal amperage
  • Capacitor body visibly bulged, leaking, or reads out-of-tolerance on a capacitance meter

✔ If these symptoms match and capacitor testing confirms a defective reading, this is a likely failed component. Similar symptoms can also result from wiring, a contactor, motor, compressor, or electrical-supply problems — confirm the capacitor is the root cause before ordering.

📦 Part Details

  • Part Number: 36-60R3744
  • Alternate Rotom Number: 60DVR
  • Brand: Rotom / AllTemp — New
  • Type: Single-Value Round HVAC Motor-Run Capacitor
  • Capacitance: 60MFD / 60 µF (±5%)
  • Voltage Rating: 370/440 VAC (dual-voltage)
  • Shape: Round
  • Diameter: 2.17 in / 55 mm
  • Height: 5.12 in / 130 mm
  • Features: Built-in pressure interrupter, UL and cUL Recognized
  • Compatibility: Specification-based — match capacitance, voltage, shape, and dimensions to original

🔄 Also Replaces These Part Numbers

Direct round replacements (60MFD, 370/440V, round):
60DVR (Rotom alternate), TRCF60 (Titan Pro / Packard), PRCF60 (Packard), PRCF60A (Titan HD), PPS60440RD (ProParts), PPHD60440RD (ProParts HD), 45600R (DiversiTech), TP60440R (TradePro), TP60440U (TradePro HD), CR60X440R (Supco), LCR60X440R (Supco Linebacker), 12254 (MARS), 12754 (JARD), 14254 (MARS USA), USA2219 (AmRad)

Electrical equivalents — oval shape (confirm mounting fit before ordering):
An oval 60MFD capacitor may be electrically equivalent, but mounting and enclosure clearance must be confirmed. 36-60-370440 (Rotom oval), TOCF60 (Titan Pro), POCF60 (Packard), CR60X440 (Supco), LCR60X440 (Supco Linebacker), 12051 (MARS), 12951 (JARD), 14051 (MARS USA), 45600H (DiversiTech) — same 60MFD and 440V electrical rating; oval case requires confirmation that a different mounting strap and enclosure clearance can be accommodated.

⚠️ Recommended While Servicing:
Inspect the contactor while the unit is open and replace it only when testing or visible damage (pitting, burning) confirms it is defective. If the motor shows signs of overheating or bearing wear, address it at the same service call to avoid a repeat visit.

⚙️ Installation

Skill Level: Advanced — Qualified HVAC Technician Required. Disconnect and lock out all power to the unit before opening the electrical compartment. Diagnosis and replacement should be completed by a qualified HVAC technician. Photograph the original wiring before disconnecting. Connect the replacement to the same terminals and confirm all connections are secure before restoring power and testing motor operation.

✓ Specification Compatibility

This capacitor is compatible with any HVAC motor application requiring a single-value round motor-run capacitor rated at exactly 60MFD and 370V or 440V, provided the round body (2.17" diameter × 5.12" height) fits the existing mounting bracket. Compatibility is determined by electrical specification and physical fit — not by equipment model number. Contact us with your original capacitor label before ordering if you are unsure.

💡 Pro Tip

Use a Capacitor Tester — Not a Multimeter:
A standard multimeter cannot accurately measure capacitance. Use a dedicated capacitor tester or a multimeter with a capacitance function to confirm the original capacitor reads outside the ±5% tolerance before condemning it. A capacitor reading within tolerance is not the cause of the motor problem — look further before ordering a replacement.

✅Compatibility & Cross Reference

Direct Round Replacements — 60MFD, 370/440V, Round

60DVR (Rotom alternate), TRCF60 (Titan Pro / Packard), PRCF60 (Packard), PRCF60A (Titan HD), PPS60440RD (ProParts), PPHD60440RD (ProParts HD), 45600R (DiversiTech), TP60440R (TradePro), TP60440U (TradePro HD), CR60X440R (Supco), LCR60X440R (Supco Linebacker), 12254 (MARS), 12754 (JARD), 14254 (MARS USA), USA2219 (AmRad)

Electrical Equivalents — Oval Shape (Confirm Mounting Fit Before Use)

36-60-370440 (Rotom oval), TOCF60 (Titan Pro), POCF60 (Packard), CR60X440 (Supco), LCR60X440 (Supco Linebacker), 12051 (MARS), 12951 (JARD), 14051 (MARS USA), 45600H (DiversiTech) — same 60MFD and 440V electrical rating; oval case requires confirmation that a different mounting strap and enclosure clearance can be accommodated.

370V-Only References — Do Not Use in 440V Applications

TRC60, 12227, 12727, RCR60-370X — these may replace 36-60R3744 only when the equipment manufacturer specifies a 370V capacitor. A 370V capacitor must not replace a capacitor required to operate at 440V.

No verified exact equipment models confirmed. Specification-based HVAC replacement: 60MFD, 370/440 VAC, round case. Verify capacitance, voltage, and dimensions before ordering.

Not sure about your model number? Call 1-877-899-7278 and we’ll help you confirm. All brand names are the property of their respective owners and are used for compatibility reference only.