Refrigerator Not Making Ice or Dispensing Water? Inlet Valve W11567335 – Fix No-Flow Fast
A failed water inlet valve is the most common cause of no ice production and no water dispenser output in Whirlpool-built refrigerators. In most Whirlpool, Maytag, and KitchenAid refrigerators, the water inlet valve is an electrically operated solenoid valve that controls water flow from the household supply line to the ice maker and dispenser. When it fails — due to a burned solenoid, mineral buildup, or a cracked valve body — water stops flowing entirely, the ice maker goes dry, and the dispenser produces nothing. ⚡ One of the most common failure points in Whirlpool-platform refrigerators with ice and water dispensers. Part W11567335 is the genuine OEM replacement inlet valve that restores full water flow to the ice maker and dispenser immediately.
❓ Is This the Right Part?
This is the correct fix if ALL of the following are true:
- ✔ Refrigerator powers on and cools normally
- ✔ Household water supply line is connected, turned on, and pressure is confirmed adequate (min. 20 PSI)
- ✔ Water filter has been replaced recently and is not clogged
- ✔ ONLY problem is no water from dispenser or no ice production
Not sure? Send us your model number — we'll confirm before you order.
🔧 Common Symptoms
- Ice maker stops producing ice entirely
- Water dispenser produces no water or only a trickle
- Humming sound from the back of the fridge when dispenser is activated — valve energizes but doesn’t open
- Visible water leak at the valve body or inlet fitting
✔ If these symptoms match, this is the most likely failed component in the water supply system.
✔ In most cases, replacing this inlet valve restores full ice and water dispenser function immediately.
📦 Part Details
- Part Number: W11567335
- Type: Refrigerator Water Inlet Valve — dual-solenoid electrically operated valve controlling flow to ice maker and water dispenser
- Replaces: W11567335 (OEM direct)
- Brands: Whirlpool, Maytag, KitchenAid, Amana
While the valve is out, replace the refrigerator water filter if it hasn’t been changed in the last 6 months. A clogged filter restricts flow and puts back-pressure on the new valve — installing a fresh filter at the same time protects the repair and maximizes water flow immediately.
⚙️ Installation
Skill Level: Moderate — 20–30 minutes. Disconnect power and shut off the water supply before servicing. Pull the refrigerator away from the wall and access the valve at the lower rear. Disconnect the water supply line, outlet tubes, and wiring harness from the old valve, transfer them to the new W11567335, and secure the valve to the mounting bracket. Restore water supply and power, then run the dispenser for 2–3 minutes to purge air and confirm full flow.
✓ Compatible Models
Confirmed compatible with Whirlpool, Maytag, and KitchenAid refrigerator models using the W11567335 water inlet valve. Contact us to verify your model number before ordering.
💡 Pro Tip
Before replacing the valve, test each solenoid coil with a multimeter set to resistance mode — a functional solenoid reads 200–500 ohms. An open circuit (OL) confirms the solenoid has burned out and the valve needs replacement. This 2-minute test eliminates guesswork and confirms the valve is the root cause before you order.