WP3399849 Dryer Thermal Fuse
WP3399849 Dryer Thermal Fuse
WP3399849 Dryer Thermal Fuse
WP3399849 Dryer Thermal Fuse

Whirlpool Dryer Thermal fuse WP3399849, Replaces 3399849

XPart Number XP10003310
Sale price
$24.99
Regular price
$29.37
In stock and ready for shipping
Buying Options: XPart Premium

Product variant with selected options does not exist!

Frequently Bought Together

Check Fit & Find Parts
Bubba checks verified models, product descriptions, cross-references and store data. Find your model number →
DRYER WILL NOT START OR TUMBLE WHEN THE FUSE IS OPEN

Whirlpool Dryer Thermal fuse WP3399849, Fixes Dryer will not start or tumble when the fuse is open

Genuine Whirlpool non-resettable dryer thermal fuse, rated approximately 91°C/196°F, with two 1/4-inch terminals. The fuse opens the heating circuit when the dryer overheats.

Part WP3399849Replaces 3399849Whirlpool
Guaranteed to Fit — or your money back.
Confirm your full appliance model number before ordering.

Is This the Right Part?

Part NumberWP3399849
Replaces3399849
ManufacturerWhirlpool
Appliance TypeDryer
Part TypeThermal fuse

✅ Cross Reference Information

Current Part NumberWP3399849
Replaces3399849

Common Symptoms

  • Dryer does not start or the motor does not run.
  • Dryer may have no heat when the fuse is open in a heating-related circuit.
  • Fuse repeatedly opens after replacement because of restricted exhaust airflow, lint buildup, overload, or another overheating condition.

Check Before Replacing

  • Disconnect electrical power before accessing or testing the fuse.
  • With the dryer unplugged, disconnect the wires from the fuse and test continuity across its two terminals with a multimeter.
  • A good fuse should show continuity; an open or no-continuity reading indicates the fuse has opened and requires replacement.
  • Do not bypass or jumper the thermal fuse. Before installing a replacement, inspect the lint screen and exhaust path for blockage and confirm that the dryer is not overloaded.
  • Use the appliance's model-specific service documentation for access-panel removal and circuit testing; do not infer a fault from a symptom alone.

Pro Tip

If WP3399849 is open, check and correct restricted venting or lint accumulation before operating the dryer with a replacement fuse, because the fuse is a one-time overheat protection device.

Part Details

Part NumberWP3399849
Part TypeThermal fuse
ManufacturerWhirlpool
Appliance TypeDryer
Primary FunctionNon-resettable safety fuse in the dryer circuit that opens when excessive temperature is detected, interrupting power to protect the appliance from overheating.

Installation Notes

  • Disconnect power before servicing or installing the fuse.
  • Access and panel-removal steps vary by dryer model; follow the model-specific Whirlpool service documentation.
  • Remove and reconnect the two fuse wires only with power disconnected, preserving their original terminal locations.
  • Install the exact WP3399849 replacement and do not substitute a resettable fuse or bypass wire.
  • After replacement, verify the dryer operates normally and investigate any recurring overheat condition.

Verified Compatible Models

3LTE5243BN0, 3LTE5243BW0, 11088182890, 11088182891, 11088752793, 11088754792, 11088754793, 11098518410, LER3622DQ1, LER3622DQ2, LER3622DZ1, LER3622DZ2, LER3622HQ0, LER3622HQ1, LER3622PQ0

Fitment reminder: Match the complete appliance model number, including suffix or revision where applicable, before ordering.

Buy Online Pick Up In-Store

Address
101 Trillium Dr
Kitchener, Ontario N2E 1W8
Hours
Mon–Fri 9 AM–5 PM • Sat 9 AM–1 PM