Samsung Dryer Heating Element DC47-00032A, Replaces DC93-00154A, DC97-14486E, XP93-00154A
Samsung Dryer Heating Element DC47-00032A — Fix Dryer That Won't Heat or Blows Cold Air
Samsung Dryer Heating Element DC47-00032A — Fix Dryer That Won't Heat or Blows Cold Air
Samsung Dryer Heating Element DC47-00032A — Fix Dryer That Won't Heat or Blows Cold Air

Samsung Dryer heater DC47-00032A

XPart Number XP10009602
Sale price
$63.99
Regular price
$88.28
In stock and ready for shipping
Buying Options: XPart Premium

Product variant with selected options does not exist!

Frequently Bought Together

Check Fit & Find Parts
Bubba checks verified models, product descriptions, cross-references and store data. Find your model number →
DRYER NOT HEATING (DRUM TUMBLES BUT NO HEAT)

Samsung Dryer heater DC47-00032A, Fixes Dryer not heating (drum tumbles but no heat)

Samsung electric-dryer heater element rated AC 240 V, 3700 W + 1500 W (5200 W total).

Part DC47-00032ASamsung
Guaranteed to Fit — or your money back.
Confirm your full appliance model number before ordering.

Is This the Right Part?

Part NumberDC47-00032A
ManufacturerSamsung
Appliance TypeDryer
Part TypeDryer heater

✅ Cross Reference Information

Current Part NumberDC47-00032A

Common Symptoms

  • Dryer not heating (drum tumbles but no heat)
  • Clothes taking too long to dry
  • Dryer overheating or getting too hot
  • Visible damage to element coil (breaks, burns, or separation)
  • Burning smell during operation
  • Only one heat setting working (high or low)
  • Circuit breaker tripping when dryer starts
  • Dryer heating intermittently
  • Weak or insufficient heat
  • Dryer running but not drying clothes
  • Element glowing but not producing enough heat

Pro Tip

The DC47-00032A is a 3-wire dual wattage element—correct wiring is critical for proper operation.

Part Details

Part NumberDC47-00032A
Part TypeDryer heater
ManufacturerSamsung
Appliance TypeDryer

Installation Notes

  • CRITICAL SAFETY WARNING:
  • This repair involves 240V electrical connections and disassembly of the heater housing. Always unplug the dryer and turn off the circuit breaker before beginning work to prevent electrical shock. This is an advanced repair requiring careful attention to coil positioning, insulator placement, and correct 3-wire connections. If uncomfortable with this repair, hire a qualified technician.
  • Turn off the circuit breaker
  • supplying power to the dryer at the main electrical panel.
  • CRITICAL:
  • Electric dryers operate on 240V AC—turning off the breaker is essential for safety.
  • Unplug the dryer
  • from the electrical outlet (or verify power is off if hardwired).
  • Verify power is off
  • using a non-contact voltage tester at the dryer terminal block.
  • Move the dryer
  • away from the wall to access the rear panel. You may need assistance—dryers are heavy.
  • Disconnect the dryer vent hose
  • from the rear of the dryer by loosening the clamp.
  • Take multiple photos
  • of the dryer rear panel, heating element location, and all wire connections before disassembly. This is absolutely critical for proper reassembly, especially for the 3-wire configuration.
  • Remove the rear access panel
  • by removing the screws around the perimeter (typically 8-12 screws). Set the panel aside.
  • Locate the heating element assembly
  • in the lower rear section of the dryer (large rectangular metal housing with ducts).
  • Take detailed close-up photos
  • of all wire connections to the heating element terminals (3-wire configuration), thermal fuse, and thermostats from multiple angles.
  • Note which wire connects to which terminal—incorrect wiring causes heating failure.
  • Disconnect the wire connectors
  • from the heating element terminals by pulling the spade connectors straight off. Do not pull on wires—grip the connectors.
  • Important:
  • The DC47-00032A has 3 terminals—two single-wire terminals and one double-wire terminal. Document which wires connect to which terminals.
  • Disconnect the thermal fuse wires
  • (two wires connected to the thermal fuse mounted on the heater housing).
  • Disconnect any thermostat wires
  • (high-limit thermostat, cycling thermostat if mounted on housing).
  • Remove the heating element assembly
  • from the dryer (remove mounting screws and duct connections) and place on a clean work surface.
  • Inspect the heater housing
  • for damage, cracks, or warping. Replace if damaged.
  • Remove the heater housing cover screws
  • (typically 4-8 screws around the perimeter of the housing). Carefully remove the cover.
  • Take detailed photos
  • of the old element coil position, insulator placement, and terminal connections inside the housing before removal.
  • Disconnect the internal wire connections
  • from the element coil terminals inside the housing.
  • Carefully remove the old heating element coil
  • from the housing, noting the position of ceramic insulators and coil supports.
  • Caution:
  • Handle carefully—ceramic insulators are fragile.
  • Inspect the old element coil
  • for visible damage such as breaks, burns, or separation. This confirms the diagnosis.
  • Test the old element coil with a multimeter
  • set to measure resistance (ohms). For the DC47-00032A dual wattage element: Test between the two single-wire terminals—should read approximately 15-16 ohms (3700W circuit). Test between one single-wire terminal and the double-wire terminal—should read approximately 38-40 ohms (1500W circuit). Infinite reading = broken element.
  • Test the thermal fuse
  • with a multimeter—should show continuity (0 ohms) when good. Infinite reading = blown fuse.
  • Replace thermal fuse if blown—element won't heat without it.
  • Test the high-limit thermostat
  • with a multimeter—should show continuity when cool. Replace if failed.
  • Check for airflow restrictions
  • that caused element failure: clean lint filter thoroughly, inspect and clean exhaust vent duct (remove all lint buildup), verify vent hood outside opens freely, inspect blower housing for lint buildup.
  • Restricted airflow causes overheating and repeat failures.
  • Clean the heater housing
  • interior of any debris, dust, or corrosion.
  • Inspect all ceramic insulators
  • for cracks or damage. Replace damaged insulators—they are critical for electrical isolation and coil support.
  • Unpack the new DC47-00032A heating element coil
  • from its packaging. Handle carefully—avoid bending or damaging the coil.
  • Compare the new coil to the old one
  • to verify dimensions, terminal configuration (3-wire), and coil shape match.
  • Inspect the new coil
  • for any shipping damage before installation.
  • Test the new element coil with a multimeter
  • (optional)—should read approximately 15-16 ohms between the two single-wire terminals, 38-40 ohms between one single-wire terminal and the double-wire terminal.
  • Position the ceramic insulators
  • in the heater housing according to your detailed photos. Insulators must be properly positioned to support the coil and prevent shorts to the housing.
  • Carefully install the new heating element coil
  • in the housing, threading it through the ceramic insulators.
  • Ensure the coil does not touch the metal housing—ceramic insulators must provide complete electrical isolation.
  • Position the coil terminals
  • so they extend through the housing wall for external wire connections.
  • Connect the internal wires
  • (if applicable) to the element coil terminals inside the housing according to your photos.
  • Verify the coil is properly supported
  • by all ceramic insulators with no contact to metal housing. Check clearance on all sides—minimum 1/4-inch clearance required.
  • Reinstall the heater housing cover
  • and install the mounting screws. Tighten firmly but not excessively.
  • Reinstall the heating element assembly
  • in the dryer cabinet, installing mounting screws and reconnecting duct connections.
  • Reconnect the wire connectors
  • to the heating element terminals.
  • CRITICAL 3-WIRE CONNECTION:
  • The DC47-00032A has specific wiring requirements. Typically: two wires connect to the double-wire terminal (common), one wire connects to each single-wire terminal (high and low heat circuits). Verify correct connections against your detailed photos. Incorrect wiring causes heating failure or element damage.
  • Reconnect the thermal fuse wires
  • to the thermal fuse terminals.
  • Reconnect any thermostat wires
  • to their original positions.
  • Verify all electrical connections are secure
  • by gently tugging on each wire connector.
  • Double-check all connections
  • against your detailed photos to ensure correct installation, especially the 3-wire element connections.
  • Verify no wires are pinched or crushed
  • between panels or components.
  • Reinstall the rear access panel
  • by positioning it and installing the mounting screws. Tighten firmly.
  • Reconnect the dryer vent hose
  • to the rear of the dryer and secure with the clamp. Ensure the connection is tight with no gaps.
  • Move the dryer back
  • to its installation location.
  • Restore power
  • by turning on the circuit breaker.
  • Plug in the dryer
  • (if unplugged).
  • Run a test cycle
  • (timed dry, high heat, 15-20 minutes) with a small load of damp towels.
  • Verify the dryer heats properly on high heat
  • by feeling the exhaust air after 5 minutes—should be warm to hot (130-160°F).
  • Test low heat setting
  • (if applicable) to verify dual wattage operation—exhaust should be warm but cooler than high heat (110-130°F).
  • Listen for unusual noises
  • during operation—dryer should run smoothly.
  • Check for burning smells
  • (slight odor is normal from manufacturing oils burning off during first use).
  • Monitor the dryer temperature
  • to ensure it doesn't overheat—drum should be warm but not too hot to touch.
  • Verify clothes dry properly
  • in the expected time (typically 40-60 minutes for a full load).
  • If the dryer heats properly on both settings and dries clothes efficiently
  • , the repair is complete.
  • Safety Notes:
  • Always unplug the dryer and turn off the circuit breaker before working on 240V systems. Take extensive photos during disassembly, especially of the 3-wire connections. Clean lint filter and exhaust vent thoroughly before operating. Test old element and thermal fuse with multimeter to confirm failures. Verify correct 3-wire connections—incorrect wiring causes heating failure. Ensure ceramic insulators properly support coil with no metal contact. This repair requires advanced mechanical and electrical skills.

Verified Compatible Models

DV42H5600EG/A3, DV42H5600EP/A3-00, DV42H5600EP/A3-01, DV42H5600EP/A3-02, DV42H5600EP/A3-03, DV42H5600EP/AC-01, DV42H5600EP/AC-02, DV42H5600EP/AC-03, DV42H5600EW/A3-00, DV435ETGJRA/A1-01, DV435ETGJWR/A1-01, DV455EVGSGR/AA-01, DV455EVGSGR/AA-02, DV455EVGSWR/AA-00, DV455EVGSWR/AA-01, DV455EVGSWR/AA-02, DV457EVGSGR/AA-00, DV457EVGSGR/AA-01, DV457EVGSGR/AA-02, DV457EVGSGR/AA-0F, DV457EVGSWR/AA-00, DV457EVGSWR/AA-01, DV457EVGSWR/AA-02, DV45H6300EG/A3-00, DV45H6300EW/A3-00, DV45H6300EW/A3-01, DV45H6300EW/A3-02, DV45H6300EW/A3-03, DV45K6200EW/A3-00, DV45K6200EW/A3-01, DV45K6200EW/A3-02, DV45K6200EZ/A3, DV45K6200EZ/A3-00, DV45K6200EZ/AC, DV45K6500EV/A3-00, DV45K6500EV/AC, DV45K6500EW/A3-00, DV45K6500EW/A3-01, DV45K6500EW/A3-02, DV45K7100EW/A3, DV45K7100EW/A3-00, DV45K7600EW/A3-00, DV45K7600EW/AC, DV48J7700EW/A2, DV48J7700EW/A2-00, DV48J7700EW/A2-01, DV48J7700EW/A2-02, DV48J7770EP/A2, DV48J7770EP/A2-01, DV48J7770EP/A2-02, DV48J7770EW/A2, DV48J7770EW/A2-01, DV48J7770EW/A2-02, DV48J7770EW/AC, DV50K7500EV/A3, DV50K7500EV/A3-00, DV50K7500EV/A3-01, DV50K7500EV/AC, DV50K7500EW/A3, DV50K7500EW/A3-00, DV50K7500EW/A3-01, DV50K8600EV/A3-00, DV50K8600EV/A3-01, DV50K8600EV/AC, DV50K8600EW/A3-00, DV50K8600EW/A3-01, DV511AER/XAA-00, DV511AER/XAA-01, DV511AER/XAA-02, DV511AEW/XAA-00, DV511AEW/XAA-01, DV511AEW/XAA-02, DV520AEP/XAA-00, DV520AEP/XAA-01, DV520AEP/XAA-02, DV520AEP/XAC, DV520AEW/XAA-00, DV520AEW/XAA-01, DV520AEW/XAA-02, DV520AEW/XAA-03, DV52J8700EP/A2, DV52J8700EP/A2-01, DV52J8700EP/AC, DV52J8700EW/A2, DV5451AEW/XAA-01, DV56H9000EP/A2-00, DV56H9100EW/A2-00, DVE45A6400V/A3, DVE45A6400W/A3, DVE45M5500P/A3, DVE45M5500P/A3-00, DVE45M5500W/A3, DVE45M5500W/A3-00, DVE45M5500Z/A3, DVE45M5500Z/A3-00, DVE45R6300C/A3, DVE45R6300C/A3-00, DVE45R6300V/A3, DVE45R6300V/A3-00, DVE45R6300W/A3, DVE45R6300W/A3-00, DVE45T6200W/A3, DVE45T6200W/A3-00, DVE46BG6500VA3, DVE50A8500V/A3, DVE50A8500V/A3-00, DVE50A8600E/A3, DVE50A8600E/A3-00, DVE50A8600V/A3, DVE50A8600V/A3-00, DVE50A8800V/A3, DVE50BG8300EA3, DVE50BG8300VA3, DVE50R8500V/A3, DVE50R8500V/A3-00, DVE50R8500V/AC, DVE50R8500W/A3, DVE50R8500W/A3-00, DVE52A5500C/A3, DVE52A5500C/A3-00, DVE52M7750V/A3-00, DVE52M7750W/A3-00, DVE52M8650V/A3-00, DVE52M8650W/A3-00, DVE53BB8700TA3, DVE53BB8900DA3, DVE53BB8900TA3, DVE54CG7550VA3, DVE54M8750V/A3, DVE54M8750V/A3-00, DVE54M8750W/A3, DVE54M8750W/A3-00, DVE54R7600C/A3-00, DVE54R7600V/A3-00, DVE54R7600W/A3-00, DVE55A7300E/A3-00, DVE55A7700V/A3-00, DVE55CG7500EA3, DVE55M9600V/A3-00, DVE55M9600W/A3-00, DVE60A9900V/A3-00, DVE60M9900V/A3-00, DVE60M9900W/A3-00