Whirlpool Range / Cooktop Range 4-point re-ignition spark module WPW10475147, Fixes Surface burner does not spark or will not light
Whirlpool OEM 4-point re-ignition spark module for gas range and cooktop surface-burner ignition. The redesigned part may differ in appearance from the original while retaining the same function.
Confirm your full appliance model number before ordering.
Is This the Right Part?
✅ Cross Reference Information
Common Symptoms
- One or more surface burners produce no spark.
- Burner ignition is weak or intermittent.
- Igniters continue sparking after a burner has ignited.
Check Before Replacing
- Observe whether the affected burner produces no, weak, or intermittent spark.
- Before condemning the spark module, inspect the affected spark electrode and spark wire, since either can cause similar symptoms.
- Disconnect electrical power before accessing or testing the module.
Pro Tip
Part Details
Installation Notes
- Disconnect electrical power before installation.
- For gas cooktops or ranges, shut off the gas supply before accessing the component.
- Record wire locations before disconnecting the old module and restore each wire to its original location.
Verified Compatible Models
CCGP2420P, CCGP2420PF, CCGP2420PG, CCGP2420PR, CCGP2420PU, CCGP2720P, CCGP2720PG, CCGP2720PK, CCGX2420B, CCGX2420W, CVDX4180W, CVGX2423B, CVGX2423B18, CVGX2423Q, CVGX2423W, KDRS463VSS04, KDRS467VBK00
Fitment reminder: Match the complete appliance model number, including suffix or revision where applicable, before ordering.
Buy Online Pick Up In-Store