WR01F02479 Dryer Heating Element

Sale price
$129.99
Regular price
$191.36
You save
$61.37 (32%)

XPart Number: 9665366688033   |   GTIN: 100094970502

Frequently Bought Together

Heating Element Assembly, Heater Assembly, Dryer Heater, Electric Heating Element, Heating Coil Assembly, Complete Heater Housing Unit

WR01F02479, WR01F02479A, WR01F02479B, AP6331670, PS12745416, EAP12745416

GE, Hotpoint

Fits Models: (Ctrl+F and Enter Your Model Number)

GEGTD33EASK0WW, GTD33EASK1WW, GTD33EASK2WW, GTD33GASK0WW, GTD33GASK1WW, GTD33GASK2WW, GTD42EASJ0WW, GTD42EASJ1WW, GTD42EASJ2WW, GTD42GASJ0WW, GTD42GASJ1WW, GTD42GASJ2WW, GTD45EASJ0WW, GTD45EASJ1WW, GTD45EASJ2WW, GTD45GASJ0WW, GTD45GASJ1WW, GTD45GASJ2WW, GTD65EBSJ0DG, GTD65EBSJ1DG, GTD65EBSJ2DG, GTD65GBSJ0DG, GTD65GBSJ1DG, GTD65GBSJ2DG, GTD72EBSN0DG, GTD72EBSN1DG, GTD72EBSN2DG, GTD72GBSN0DG, GTD72GBSN1DG, GTD72GBSN2DG, GTD75ECPLDG, GTD75GCPLDG, GTD76ECPLDG, GTD76GCPLDG

HotpointHTX24EASK0WW, HTX24EASK1WW, HTX24EASK2WW, HTX24GASK0WW, HTX24GASK1WW, HTX24GASK2WW, HTX27EASK0WW, HTX27EASK1WW, HTX27EASK2WW, HTX27GASK0WW, HTX27GASK1WW, HTX27GASK2WW

Professional Repair Time: 30-45 minutes
DIY Repair Time: 60-90 minutes
Difficulty Rating: Moderate-Advanced (3.5/5) — Requires advanced mechanical and electrical skills, dryer disassembly, 240V electrical knowledge, multimeter testing, careful wire handling

CRITICAL SAFETY WARNING: This repair involves 240V electrical connections. Always turn off the circuit breaker before beginning work. If uncomfortable with electrical systems, hire a qualified technician.

  1. Turn off the circuit breakerĀ supplying power to the dryer at the main electrical panel.
  2. Unplug the dryerĀ (if accessible) for additional safety.
  3. Verify power is offĀ using a non-contact voltage tester.
  4. Disconnect the exhaust vent hoseĀ from the rear of the dryer.
  5. Pull the dryer away from the wallĀ to access the rear panel.
  6. Take multiple photosĀ of the heating element installation and all wire connections before disassembly.
  7. Remove the rear access panelĀ (typically 6-10 Phillips screws around perimeter).
  8. Label all wire connectionsĀ with tape indicating positions (L1, L2, thermostat, thermal fuse).
  9. Take detailed photosĀ of wire colors and terminal positions.
  10. Disconnect all electrical wiresĀ by removing spade connectors or loosening screw terminals. Grip connectors, not wires.
  11. Remove heating element mounting screwsĀ (typically 2-4 screws).
  12. Carefully remove the old heating elementĀ from the cabinet. Wear gloves—housing may have sharp edges.
  13. Inspect the old elementĀ for broken coil, blown thermal fuse, corroded terminals, or damaged housing.
  14. Test the old element with a multimeterĀ set to measure resistance. Should read 8-12 ohms between power terminals. Infinite reading = broken coil. Test for continuity to housing (ground)—should be infinite (no short circuit).
  15. Test thermal fuse and thermostatĀ for continuity—both should show continuity when cool.
  16. Inspect exhaust vent system thoroughlyĀ for blockages.Ā CRITICAL:Ā Blocked vents are the #1 cause of element failure. Clean entire vent from dryer to outside cap.
  17. Clean blower housing and wheelĀ to remove lint buildup.
  18. Inspect heating element mounting areaĀ and clean if necessary.
  19. Unpack the new WR01F02479 heating elementĀ carefully.
  20. Compare new element to oldĀ to verify dimensions, terminal positions, and mounting holes match.
  21. Inspect new elementĀ for any shipping damage.
  22. Test new element with multimeterĀ (optional)—should read 8-12 ohms, no continuity to housing.
  23. Position new elementĀ in cabinet, aligning mounting holes and ensuring terminals are accessible.
  24. Install mounting screwsĀ and tighten firmly but not excessively.
  25. Verify element is securely mountedĀ with no movement.
  26. Reconnect all electrical wiresĀ according to photos and labels. Push spade connectors firmly onto terminals.Ā CRITICAL:Ā Incorrect wiring creates fire hazards.
  27. Verify all connections are secureĀ by gently tugging each wire.
  28. Double-check all wire connectionsĀ against photos.
  29. Ensure no wires touch the heating element housingĀ or hot surfaces.
  30. Reinstall rear access panelĀ and tighten screws in cross-pattern.
  31. Reconnect exhaust vent hoseĀ and secure with hose clamp.
  32. Push dryer backĀ toward wall, leaving 4-6 inches clearance.
  33. Restore powerĀ by turning on circuit breaker.
  34. Plug in dryerĀ (if unplugged).
  35. Run test cycleĀ (timed dry, high heat) for 3-5 minutes.
  36. Verify heating—open door briefly and feel for warm/hot air in drum.
  37. Listen for unusual noises—should operate smoothly.
  38. Check outside vent capĀ for strong, warm air flow.
  39. Monitor temperatureĀ during first 10-15 minutes—element should cycle on/off.
  40. Run complete drying cycleĀ with small load to verify proper drying performance.
  41. If element operates properly and clothes dry effectively, repair is complete.

Safety Notes: Always turn off circuit breaker before working on 240V systems. Clean exhaust vents before installing new element. Label all wires before disconnecting. Take detailed photos. Test element with multimeter to confirm failure. Do not overtighten screws or terminals. This repair requires advanced mechanical and electrical skills.

  1. Always clean the exhaust vent system before replacing the heating element—blocked vents cause 90% of element failures. Clean from dryer to outside vent cap and verify strong air flow.
  2. Test the element with a multimeter before replacement. Should read 8-12 ohms between power terminals. Infinite = broken coil. Also test for shorts to housing—should be infinite resistance.
  3. The element operates at 240V AC and draws 20-25 amps—correct wiring is critical. Label all wires and take detailed photos before disconnecting. Incorrect wiring causes fire hazards.
  4. The high-limit thermal fuse (250°F-280°F) is a one-time safety device. Once blown, it must be replaced. If it blows repeatedly, fix the root cause (blocked vent, blower failure) first.
  5. The operating thermostat (130°F-150°F) cycles the element on/off. If stuck closed, dryer overheats. If stuck open, no heating occurs.
  6. Verify the element is firmly mounted before connecting wires. Loose elements vibrate and cause wire connection failures.
  7. The nichrome coil must never touch the metal housing—this causes immediate short circuit failure. Ceramic insulators prevent contact. Inspect before installation.
  8. Heating elements typically last 8-12 years with proper maintenance. Blocked vents, overloading, and dirty lint filters shorten element life significantly.
  9. Monitor the dryer during first few cycles after replacement. Check for proper heating, normal cycling, no unusual noises, and proper drying time (30-60 minutes).
  10. The complete assembly includes housing, coil, thermal fuse, and thermostat—all replaced together. More reliable than replacing individual components.
  • Dryer not heating at all
  • Dryer heating intermittently or cycling rapidly
  • Dryer overheating or getting too hot
  • Clothes taking too long to dry
  • Dryer tripping circuit breaker
  • Burning smell during operation
  • Thermal fuse repeatedly blowing
  • Heating element coil broken or burned
  • Visible damage to element housing
  • Error codes indicating heating fault
  • Weak or insufficient heat
  • Temperature not reaching proper level
  • Dryer running but producing no heat
  • Short circuit to housing
  • Corroded electrical terminals
  • Thermostat failure
  • Insulator damage


Whirlpool refrigerator replacement parts, Frigidaire refrigerator replacement parts, GE refrigerator replacement parts, Kenmore refrigerator replacement parts, KitchenAid refrigerator replacement parts, LG refrigerator replacement parts, Maytag refrigerator replacement parts, Whirlpool refrigerator drawers and glides replacement, Whirlpool dishwasher replacement parts, GE dishwasher replacement parts, KitchenAid dishwasher replacement parts, Maytag dishwasher replacement parts, Frigidaire dishwasher replacement parts, Kenmore dishwasher replacement parts, Whirlpool washer replacement parts, GE washer replacement parts, Maytag washer replacement parts, Kenmore washer replacement parts, LG washer replacement parts, Whirlpool dryer replacement parts, GE dryer replacement parts, Maytag dryer replacement parts, Kenmore dryer replacement parts, LG dryer replacement parts, Whirlpool range replacement parts, GE range replacement parts, Whirlpool stove replacement parts, GE stove replacement parts, GE oven replacement parts, GE microwave replacement parts, buy Whirlpool refrigerator parts online, buy GE dishwasher parts online, replacement Kenmore washer parts for sale, buy Maytag dryer parts, LG washer replacement parts online, KitchenAid refrigerator parts for sale, Whirlpool stove and range replacement parts

WR01F02479 Dryer Heating Element

The WR01F02479 is a genuine OEM dryer heating element assembly for GE and Hotpoint electric dryers. This complete assembly includes the metal housing (galvanized steel rated for 500°F), nichrome heating coil (5000-5400 watts at 240V AC), ceramic insulators, electrical terminals, high-limit thermal fuse (250°F-280°F cutoff), and operating thermostat (130°F-150°F cycling). The assembly measures approximately 10-14 inches length x 8-10 inches width x 3-5 inches depth, weighing 3-5 pounds. It mounts inside the dryer cabinet in the air flow path between the blower and drum. The heating element operates through electrical resistance heating: when activated, 240V AC power flows through the nichrome coil, generating 300-400°F heat. The blower draws room air through the heater box, heating it to 130-160°F before entering the drum. The operating thermostat cycles the element on/off to maintain proper temperature, while the high-limit thermal fuse provides safety protection by cutting power if temperature exceeds safe limits. The element typically draws 20-25 amps and consumes 5000-5400 watts. Common failure causes include coil breakage from age or thermal cycling, thermal fuse failure from blocked exhaust vents, thermostat failure, housing corrosion, terminal corrosion, insulator damage, or coil-to-housing short circuits. Failure symptoms include no heating, intermittent heating, overheating, slow drying, circuit breaker tripping, burning smell, or error codes. The WR01F02479 replaces part numbers WR01F02479A, WR01F02479B, AP6331670, PS12745416, EAP12745416 with improved coil durability, enhanced thermostat reliability, and better housing construction. CRITICAL: Always turn off the circuit breaker before working on 240V dryer systems. Clean the exhaust vent system thoroughly before installing the new element—blocked vents are the #1 cause of heating element failure. Test the old element with a multimeter to confirm failure. This is an advanced repair requiring dryer disassembly and electrical work.

Ā 

Ā 

Key Features and Design

Crafted with advanced technology and durable materials, the WR01F02479 features a compact design that fits seamlessly into compatible dryer models for easy installation. Its robust construction helps maintain optimal heat distribution, making it a smart choice for long-lasting performance. Compatible with a wide range of models including GTUP270EM0WW and GUD27ESMM0WW, this heating element replaces outdated parts like WE11M62 to keep your appliance running smoothly.

  • High-quality materials ensure resistance to wear and heat for reliable operation.
  • Advanced heating technology promotes even drying and energy efficiency.
  • Precise compatibility with specific dryer models, making it a straightforward upgrade.

Performance and Benefits

This heating element solves the common issue of uneven drying or extended cycle times by providing steady, efficient heat that revitalizes your dryer's functionality. By upgrading with the WR01F02479, you'll experience faster drying cycles, reduced energy consumption, and improved overall appliance reliability, giving you more time for what matters most in your daily life. Trust XPart Supply Ltd. for parts that deliver real value and help extend the lifespan of your home appliances.

This WR01F02479 Dryer Heating Element is designed to provide efficient and reliable heating for your dryer. With advanced technology and high-quality materials, it ensures quick and thorough drying of your clothes. Replace your old heating element with WR01F02479 for optimal performance.

Part number WR01F02479 replaces WE11M62, WG01F01543, 189D7110G010

SupportedĀ Models:

C978-972220, C978-973220, C978-973221, CLME71214BAT00, GTUN275EM0WW, GTUP270EM0WW, GTUP270EM1WW, GTUP270EM2WW, GTUP270EM3WW, GTUP270EM4WW, GUAN275ED0WW, GUAN275ED1WW, GUAN275ED2WW, GUAP270EM0WW, GUAP270EM1WW, GUAP270EM2WW, GUAP270EM3WW, GUAP270EM4WW, GUD27EEMN0WW, GUD27ESMJ0WW, GUD27ESMJ1WW, GUD27ESMM0WW, GUD27ESMM1WW, GUD27ESPM0DG, GUD27ESPM1DG, GUD27ESSJ1WW, GUD27ESSM0WW, GUD27ESSM1WW, GUD37EEMN0DG, GUD37ESMJ0DG, GUD37ESMJ1DG, GUD37ESMM0DG, GUD37ESMM1DG, GUD57EEMT0DG, GUV27ESMW0WW, GUV27ESSM1WW, MCL1740ESBB0, MCL1740ESBB01, MCL1740ESBB02, MCL1740ESBB03, MCL1740ESBB10, MCL1740ESDG00, MCL1740ESDG01, MCL1740ESDG10, MCL1740ESGG0, MCL1740ESGG01, MCL1740ESGG02, MCL2040EPDG00, MCL2040ESBB00, MCL2040ESDG00, MCL6840ESBB0, MCL6840ESBB1, XUD27ESSM1WW

Hard to find parts? We've got them or we'll find them!

Over 10,000 New & Used Parts Ready for Pickup

Show this item number to our store staff to help locate the exact part you need
XPART GTIN/UPC NUMBER
9665366688033

XPart Supply Advantage

Your trusted partner for fast, reliable parts delivery across North America

Lightning Fast Shipping

Same-day processing with expedited delivery options across North America

Massive Inventory

Over 10,000 parts in stock and ready to ship immediately

North America Coverage

Comprehensive shipping network covering USA, Canada, and Mexico

Quality Guaranteed

Premium parts with warranty protection and expert customer support

10K+
Parts in Stock
24-48H
Local Delivery
99.8%
Customer Satisfaction
Professional appliance parts warehouse with organized shelving and extensive inventory

Express Warehouse Shipping

Order within the countdown for same-day shipping!

00 Hours
00 Minutes
00 Seconds

In stock orders placed during business hours ship the same day.

Order of $200 or more of eligible items qualify for FREE Shipping.

Same-day shipping deadline has passed

Orders placed now will ship the next business day.

Same-day shipping deadline has passed

Orders placed outside business hours will be processed when we reopen.

Business Hours: Mon–Fri 9 AM–5 PM • Sat 9 AM–1 PM

Trusted Family Business

29 years of Excellence in Appliance Parts

For over 29 years, our family has been dedicated to providing quality appliance parts and exceptional service. What started as a small local business has grown into a trusted name, but we've never forgotten our roots. Every customer receives the personal attention and care that only a family-owned business can provide.

Years of Experience

Our knowledge has been built over the past 29 years in the business, ensuring expert advice for every appliance need.

Personal Service Guarantee

We treat every customer like family, providing personalized solutions and standing behind our products.

Built on Trust

Our reputation has been built one satisfied customer at a time, creating lasting relationships in our community.

Buy Online Pick Up In-Store

Address
101 Trillium Dr
Kitchener, Ontario N2R 1J8
Phone
Hours
Mon–Fri 9 AM–5 PM • Sat 9 AM–1 PM
Get Directions

Contact Us Customer Service

Hard to find parts? We've got them or we'll find them!

Call now for expert appliance parts assistance

Business Hours: Mon–Fri 9 AM–5 PM • Sat 9 AM–1 PM