MICROWAVE WILL NOT START WITH THE DOOR CLOSED
Bosch Microswitch / microwave door interlock switch 00633795, Fixes Microwave will not start with the door closed
Genuine Bosch microswitch used as a microwave door interlock switch. The Bosch product page specifies an NO terminal on the side and a COM terminal on the bottom. The switch prevents the microwave from operating while the door is open.
Part 00633795Replaces 00415825Bosch
Guaranteed to Fit — or your money back.
Confirm your full appliance model number before ordering.
Confirm your full appliance model number before ordering.
Is This the Right Part?
Part Number00633795
Replaces00415825
ManufacturerBosch
Appliance TypeMicrowave
Part TypeMicroswitch / microwave door interlock switch
✅ Cross Reference Information
Current Part Number00633795
Replaces00415825
Common Symptoms
- Intermittent starting or operation when the door is moved
- Microwave stops shortly after starting
- Microwave does not heat because the interlock circuit prevents operation
- Door-closed status is not reliably recognized
Check Before Replacing
- Disconnect power before inspection; do not operate the microwave with the door-interlock system bypassed.
- Inspect the switch body, terminals, wiring, and door-latch actuator for visible burning, arcing, looseness, or mechanical damage.
- With the appliance unplugged and only if qualified to perform electrical testing, check the switch for consistent continuity changes as the actuator is pressed and released; compare terminal identification with the Bosch layout.
- If the switch is replaced, have the microwave interlock operation and microwave-leakage safety tested before normal use.
Pro Tip
Verify terminal orientation before installation: Bosch identifies the NO terminal on the side and the COM terminal on the bottom.
Part Details
Part Number00633795
Part TypeMicroswitch / microwave door interlock switch
ManufacturerBosch
Appliance TypeMicrowave
Primary FunctionMicrowave door-interlock microswitch that confirms the door-safe condition and prevents microwave operation when the door is open.
Installation Notes
- Disconnect electrical power before servicing.
- Install the replacement with the same terminal orientation and wiring arrangement as the original; do not bypass or defeat any interlock.
- Because microwave shielding and door interlocks require post-repair safety verification, professional installation and leakage/interlock testing are recommended.
Compatible appliance models
15 models
No matching model in this list. Use Check Fit & Find Parts to confirm compatibility.
Fitment reminder: Match the complete appliance model number, including suffix or revision where applicable, before ordering.
Buy Online Pick Up In-Store
Address
101 Trillium Dr
Kitchener, Ontario N2E 1W8
Kitchener, Ontario N2E 1W8
Phone
Hours
Mon–Fri 9 AM–5 PM • Sat 9 AM–1 PM